In our current economic conditions most companies are looking for ways to cut costs.
One way is through better management of materials in your storage silos. Many companies still use just point level sensors, like a “paddle unit”, to let them know when the material in the silo is high or low. Besides detecting high and low levels, a continuous level sensor can actually help cut costs and even increase personnel safety. Although a continuous level inventory measurement system sounds like a good idea, the inclination right now may be that “a point level works ok, no need to spend any money to upgrade or change.” So how does one justify the extra initial cost of a continuous level system?

A company in Crystal Lake with 13 silos who provides pre-blended masonry products and automated mixing stations to construction sites or as they like to call it “mortar at a push of a button” was looking for a way to better control the inventory levels of their raw materials instead of having to do a “visual”. They try to be very proactive in finding ways to make themselves more cost-efficient and effective on all levels of operation. After some research they decided to go with the SiloPatrol® cable-based smart sensor (SMU) with the SiloTrackTM inventory management software from Monitor Technologies. Even though the system cost more than they initially were willing to spend, they were able to justify the expenditure because of the added benefits of time saved not having to manually measure the material levels, better control of material inventory, and for the personnel safety reasons. Now with automatic or on-demand readings, they have better control of when they need to re-order raw materials and when the silos are getting full during refilling to prevent the downtime and clean-up costs of an over-filled silo. Plus, personnel make a lot fewer trips up the silos.

Their initial purchase was for 6 SMU’s and the SiloTrack software. Once they realized the value of the continuous level measurement system, they were able to justify the purchase of additional SMU’s for more of their silos.

 

 

SiloPatrol
Other features that they have come to appreciate about the SiloPatrol is the simplicity of installation (including wiring and set-up) for the sensor and the software, that the software works with the current PC on their desk, the sensor’s compartmental isolation of the electrical and mechanical components which eliminates much of the dust from going into the electrical area, and the ability to replace the sensor’s wiper and brush that cleans the cable without having to actually cut the cable for servicing. They also mentioned that technical support has been very responsive. They once had a computer board issue that caused software re-installation problems and technical support spent the time to talk them through the issue and shared knowledge for future prevention.

The SiloPatrol SE inventory management system is the second edition of the industry-leading cable-based smart sensor system that is designed to handle some of the harshest and most dynamic conditions imaginable. The SiloPatrol SE system incorporates state-of-the-art sensors with a wide choice of operator interfaces to fit all types of situations.

For more information, please visit
www.monitortech.com/product_conti.shtml or call us in the USA at 800-766-6486 or from anywhere at 630-365-9403. Also, check out our Level Measurement blog at http://monitortech.typepad.com.

Upcoming Shows
NPE 2009
Booth # 131019, West Hall

June 22 - 26, 2009
McCormick Place, Chicago IL
www.npe.org


We invite you to stop by our booth at NPE2009: The International Plastics Showcase. Register online as our guest to receive $20 off standard online registration fee. To Register, Visit: http://www.NPEDiscount.org/519127

 

Tech Tip: Avoid obstructions when installing a guided wave radar sensor
 

Guided wave radar instruments, like Flexar®, use a cable as a wave guide or antenna. The microwave energy pulses down the cable antenna and reflects off the material surface.
The reflected pulse travels back up the antenna to the transceiver.

Obstructions near (within ~12”) of the cable antenna have a high probability of interfering with the microwave energy measurement pulses. Just think of attempting to make a cell phone call while standing inside a metal doorway. Sometimes it works but most times it doesn’t.

Some obstructions result in crazy reflective echoes. These reflections can exceed the strength of that from the material surface. To cancel such large reflection an irritating and often substantial dead zone has to be created along the length of the wave guide cable antenna. Not good.
Obstructions also cause signal degradation. Like the cell phone example, energy from the wave guide cable can be bleed off onto the obstruction. Because the Flexar is measuring and not cooking the silo contents the emitted energy level is rather limited. If enough of this energy is bleed off there is a possibility that insufficient energy will remain to make a viable reflection.

Pictured above is one of the most common examples when it comes to interfering obstructions.

For unknown reasons the factory provided application and mounting recommendations were disregarded and the Flexar instrument was mounted to the pictured stub nozzle.

Under the best of circumstances the height of a stub nozzle should not exceed the inside diameter. In this example that guideline has been completely violated. As shown, the nozzle protruding above and below the roof line well exceed the inside diameter.

 

Flexar 1
Flexar 2
Vessel Exterior
Vessel Interior

This resulted in crazy pulse reflections which were so strong that the level signal would not follow the material level. The short term solution required a six foot dead zone to be
created on the top portion of the vessel.

This meant the customer lost the ability monitor the material in the upper six foot section of the vessel. Not good.

The long term solution is to move the Flexar to the center of the forward plate which sits atop a large nozzle which better conforms to the mounting guideline.

Please visit our blog at . . .
http://monitortech.typepad.com


Andy Bowman

Technical Services
Manager

Andy Bowman

 

 

 


Monitor Marketing Survey

Thank you
to everyone who had the opportunity to complete the Monitor Web site & Marketing Activities Survey and congratulations to the winners of the digital picture frame drawing. All of your feedback was really appreciated.
 


Securecare Profile  
Name: Jennifer Zedan
TITLE: QC Manager
DEPT: Quality Control
ANIV: June 28, 2001

Where are you from Originally?
Elgin, Illinois.

What is your favorite food?
Pizza.

What customer item reminds you most of Monitor?
Cereal.

What is the best aspect of working at Monitor?
Definitely the people, everyone goes out of
their way to help each other.

Current Projects:
Jennifer has been deligenty overseeing / administrating the ISO 9001 quality system for Monitor Technologies.

Jennifer Zedan
 

Monitor Technologies, LLC.

4W320 Keslinger Road
P.O. BOX 8048
Elburn, IL 60119-8048

800-601-5946
PH 630-365-9403
FAX 630-365-5646

 

 

www.monitortech.com
monitortech.typepad.com
www.flexar.info
monitor@monitortech.com

 

  © 2009 Monitor Technologies, LLC. All rights reserved

 

www.monitortech.com SecureCare