Gas Equipment Company is pleased to provide the e-Newsletter as a service to share useful & valuable information about the products & services we offer.  You will find sections on technical topics, new product announcements, "Did You Know" regulatory compliance requirements, "Virtual Warehouse" online ordering tips, along with an occasional "What's Wrong With This Picture?" section.  We hope you enjoy the Gas Equipment Company e-newsletter and choose to continue receiving it.  And, PLEASE feel free to email us with recommended topics or products you would like to see addressed in this forum.
 
Thank you for patronage.
 
Gas Equipment Co. will be closed
Thursday, July 4th
in Observance of Independence Day. 
Our Online Ordering System will be open with orders placed on Thursday Shipping on Friday.
July 4th
NFPA 58 Rules on Cathodic Protection
Corrosion Protection System Requirements for UG Tanks

"Did You Know?"

 UG Tank

The 2011 edition of NFPA 58 includes several changes for the installation of cathodic protection devices, which now must be installed, tested and monitored on all new underground propane-storage containers. These new rules are found in section 6.6.6.1(A)-(O).


One aspect of the new rules require a corrosion protection system shall be installed on new installations of underground steel containers, unless technical justification is provided to the authority having jurisdiction.  The corrosion protection system shall include the following: 1) a container coating complying with 5.2.1.11, 2) a cathodic protection system that consists of a sacrificial anode(s) or impressed current anode, and 3) a means to test the performance of the cathodic protection system.


Another aspect of the new rules is the cathodic protection system shall be monitored by testing and the results documented.


The sacrificial anodes shall be tested upon installation; for continued verification of the effectiveness of the system, 12-18 months after the initial test, and follow-up testing shall be performed at intervals not to exceed 36 months.


The Propane Education & Research Council has developed a training program that includes a handbook and a DVD. The video shows how to guard against corrosion of underground propane tanks and black iron or steel piping.

Electrodes

CLICK HERE for the Underground Tank Testing Flyer 

 

GEC offers marketers a number of optional testing kits and replacement maintenance products for use in the installation, testing, and maintenance of underground tank installations.

 

GEC also offers FREE training on how to measure tank-to-soil cathodic protection potentials on propane tanks.  Contact your sales representative or branch for more information on cathodic protection products, test kits, and training.

 

For more information on GEC Training programs click the link in the right hand margin with the Training Program listing. 

Documenting MANDATORY Anode Tests
NEW NFPA 58 Requirements

"TECH Topic"

Documenting MANDATORY Anode Tests
UG Tank

The 2011 edition of NFPA 58 included

several changes for the installation of cathodic protection devices, which now must be installed, tested and monitored on all new underground propane-storage containers. These new rules are found in section

6.6.6.1(A)-(O).

 

A major aspect of the new rules is the cathodic protection system shall be monitored by testing and the results documented.

 

The sacrificial anodes shall be tested upon installation; for continued verification of the effectiveness of the system, 12-18 months after the initial test, and follow-up testing shall be performed at intervals not to exceed 36 months.

 

GEC provides employee training on Cathodic Protection testing requirements and provides a sample inspection & test form as part of our curriculum.  For more information on Employee Training programs offered by GEC, CLICK the link in the right column under the heading, "EMPLOYEE TRAINING PROGRAMS."
 
Replacement Parts for Cathodic Protection Testing
Sulfate Crystals & Electrodes

"TECH Topic"

COPPER SULFATE CRYSTALS & ELECTRODES

Copper Sulfate Crystals 

Note: Under average conditions, an electrode should be emptied and cleaned out every two or three months. However, if the electrode is allowed to remain in prolonged contact with low resistivity soil or water, more frequent rejuvenation may be desirable.  For consistent results, manufacturers recommend using the highest purity CuSo4 Crystal's possible.

 

Precautions:

 

STORAGE: CuSo4 will deteriorate over time. Electrodes, which are purchased in bulk and stored for later use, should always be checked before placing into service. Copper rods can become tarnished or pitted by deteriorating CuSo4 and the CuSo4 will become unusable. The copper in this condition will become contaminated, which will cause inaccurate readings. CuSo4 should have a rich, deep blue color. If the crystals appear to have become whitened or have the appearance of being dehydrated, discard in a safe manner and replace with fresh. Do not store the electrodes in a damp atmosphere. Some types of fungus or mold can contaminate the ceramic plug assemblies. Always rotate your stock using the "FIFO" (First In, First Out) method.

 

Common Source of Error: The voltmeter used in conjunction with reference electrodes should be of sufficiently high impedance (10 megohms or greater) so that contact resistance, which can occur between electrode and soil, does not affect readings. When taking readings, the ceramic plug must come in contact with soil. Vegetation such as grass should be moved out of the way. Grass or other items will add resistance and result in inaccurate readings. Reference electrodes are designed to be durable, but over time, the ceramic plug assembly will become contaminated by foreign Half Cellmaterials and become worn or cracked. At this point, the replacement of the ceramic plug assembly is highly recommended. If the CuSo4 mixture within the electrode becomes cloudy white, reverse osmosis has occurred and rejuvenation is recommended.

 

GEC sells replacement CuSo4 copper sulfate crystals (Part # 16906, .75 lbs) for half cells.  And, replacement electrode half cells (Part # RE-5C). 

 

RegO - Dielectric Pigtails
ElectricallyRegO Logo Isolated Pigtails for Underground Containers D912 Series

 

These pigtails are designed specifically for use on Underground LP-Gas Containers where dielectric isolation is necessary to protect the container.

Dielectric Pigtails

Features:

  • Electrically insulated POL connection.
  • Heavy duty construction.
  • Individually soldered connection to the copper tubing.
  • Available in 2 styles: POL x POL & 1/4" NPT x POL 

Dielectric pigtail TBL

 

"Did You ALSO Know?"

Some Above-Ground Tank installations Require Protection

 

REGULATIONS: NFPA 58 2011 edition, Section 6.9.3.16

 Di-Electric Union

In the 2011 edition of NFPA 58 a new rule (6.9.3.16) will require underground metallic piping, tubing, or both that convey LP-Gas from a gas storage container shall require dielectric fittings at the building to electrically isolate it from the aboveground portion of the fixed piping system that enters the buildingThe dielectric fittings shall be installed above ground and outdoors.

 

It does not matter what type of tank is involved, above-ground or underground; if the installation utilizes underground metallic piping you are required to isolate the aboveground portion of fixed piping from the underground metallic piping or tubing at the building, above ground and outdoors. So all ABOVEGROUND and UNDERGROUND containers that use metallic piping or tubing, MUST incorporate a dielectric union at the house/building and it must be installed above ground and outdoors.

 

An alternative to utilization of dielectric unions in tank installations is to utilize non-metallic underground piping.  Polyethylene (PE) pipe and fittings that meet ASTM D2513 standard specifications can be used in lieu of copper or steel pipe and do not require the use of dielectric unions at the building.

PE PipeGEC sells dielectric unions for meeting this regulation and for use to isolate underground tanks from metallic underground piping.  We also carry a full line of PE pipe, fittings, couplings, risers, and accessories for various gas load size requirements.  If you need help sizing PE piping for extraordinary loads, contact one of our branches, we can run engineering analysis calculations for various gas load requirements, varying pressure requirements and pressure drops.

PERC Agricultural Equipment Rebates
$5,000 incentive available on new propane-fueled grain dryers

The Propane Education and Research Council is offering $5,000 incentive to farmers who upgrade their grain dryers.

 

With harvest season approaching, the Propane Education & Research Council (PERC) is encouraging producers to upgrade their grain dryers by offering a $5,000 incentive through the Propane Farm Incentive Program.

 

Producers who purchase a new qualifying propane-fueled dryer from GSI Group (www.gsiag.com) or Mathews Co. (www.mathewscompany.com) now through the end of 2013 can apply for the incentive through PERC's nationwide research program. In exchange, producers report post-harvest performance data to PERC. Farmers can apply by visiting dealers or submitting an online application at www.agpropane.com/incentive.

 

"New propane-fueled grain dryers can be 30 to 50% more efficient than older models," says Mark Leitman, director of marketing at PERC. "These machines can produce huge energy savings for farmers, and we offer a $5,000 incentive on select new models." 

 

The models eligible for the incentive include the GSI X-Stream series and Mathews Trilogy series dryers. PERC co-supported the development and testing of these machines.

 

The $5,000 incentive on propane-fueled grain dryers is available to qualified applicants on select models through 2013. The PERC program has already awarded more than $200,000 in incentives for irrigation engines.

 

For more information or to see a list of eligible equipment, please visit www.agpropane.com.

Gas Equipment Company TV
YouTube Channel

Gas Equipment Company is kicking off the debut of its YouTube Channel: 

GEC Color 

Gas Equipment Company TV

   

The GEC YouTube channel will be used to post useful how-to, introductory, product, and training videos.

 

The GEC YouTube channel can be accessed by clicking on the link below:
 

 

  Laughing      Joke of the Month
  
  
20 years ago we had Johnny Cash, Bob Hope and Steve Jobs.
  
Now we have no Cash, no Hope and no Jobs. Please don't let Kevin Bacon die!
  
For Specific Product or Service Questions please contact one or our Customer Service Warehouses below:

Atlanta, GA

(800) 241-4155         

Dallas, TX

(800) 821-1829

Fayetteville, NC

(800) 447-1625

Houston, TX

(800) 334-7816

Indianapolis, IN

(800) 241-1971

Kansas City, MO

(800) 821-5062

Little Rock, AR

(800) 643-8222

Orlando,  FL

(800) 821-0631

Richmond, VA

(800) 368-4013

St. Louis, MO

(800) 423-4685


Sincerely,
GEC e-Newsletter
Gas Equipment Co., Inc
In This Issue
NFPA & Cathodic Protection
Documentiing Mandatory Anode Tests
Replacement Parts for CT Testing
Di-Electric Pigtails
Aboveground Tank Protection Di-Electric Requirements
PERC Agricultural Rebates for Grain Dryers
Gas Equipment Co. TV
GEC Training Curricula
Autogas Special
Join Our Mailing List
Quick Links
  
  
Register Now to receive the GEC e-Newsletter

GEC Training Curricula Listing

 

Training List

CLICK FOR GEC TRAINING CURRICULA FLYER

Click for a PDF of GEC Training Curricula listing
AUTOGAS
DISPENSER
SPECIALS

HDP Autogas
 & Cylinder
Dispenser
Special
$ 9,649.44
DCL51DP.LGL156.1PH

Product Description 

 

DCL51DP.LGL156.1PH Modified Dispensing Cabinet package, Aluminum diamond plate exterior 51"H x 47-1/2"W x 39-1/2"D, Includes BLACKMER Model LGL156A High Differential Pressure Pump, 5HP 1PH EX Proof Motor and On/Off Switch, By-Pass Valve, Inlet & Outlet flanges, gaskets, studs & nuts, 1" ITRON Meter and All Inside Cabinet Piping, Autogas & Cylinder filling hoses, Tank to Pump plumbing Kit, Cylinder Purge Kit, Pneumatic Actuator Kit and Electrical Conduit Kit.

 

 CLICK HERE to View the CFT Catalog  

 

Click Here to View the GEC Dispenser Catalog including Cylinder & Autogas Offerings 

Do you have associates who would like to receive the e-Newsletter?   

 
 

Inet Specials

Save with Internet Specials

Visit www.gasequipment.com and shop online at the "GEC Virtual Warehouse" and take advantage of several Internet Specials. 

ALL YOU HAVE TO DO IS REGISTER FOR A WEB ORDER ENTRY (WOE) ACCOUNT WITH GEC*.  You'll be issued a confidential user I.D. and password that will allow you to order on your schedule.

Click "Register for Online Ordering" to get started.

 

*All registrants must have a current account with GEC in good standing before the WOE account can be activated.

 

For a copy of the GEC Solutions introducing our CLICK, SEARCH, BUY, MANAGE edition of our Virtual Warehouse email your request to

e-newsletter@gasequipment.com

Online Specials are changed regularly, check back periodically for new offerings!