Dear Valued Customer:

Gas Equipment Company is pleased to provide the e-Newsletter as a service to share useful & valuable information about the products & services we offer.  You will find sections on technical topics, new product announcements, "Did You Know" regulatory compliance requirements, "Virtual Warehouse" online ordering tips, along with an occasional "What's Wrong With This Picture?" section.  We hope you enjoy the Gas Equipment Company e-newsletter and choose to continue receiving it.  And, PLEASE feel free to email us with recommended topics or products you would like to see addressed in this forum.

Thank you for patronage.
Autogas Application Solution! 
Do you have an Autogas application and RegO Logoneed to take a Pump Bypass line to a  vapor splash fill opening on a domestic tank and don't have that opening?
The RegO 8118P
multi-purpose filler valve provides that solution!

The RegO 8118P Multipurpose Filler Valve can be used to replace an existing 1-1/4"NPT filler valve in a domestic 1,000WG tank.  The 8118P will provide filler valve capability into the vapor space, plus with the additional 1" NPT opening it will allow you to pipe an Autogas HDP pump bypass back to the vapor space of a domestic 1,000WG tank.  This is very helpful when using regenerative turbine pumps that are required to be piped to the vapor space of a tank.  To comply with NFPA 58 regulations it is also fitted with an excess flow seat fully contained in the tank coupling for maximum protection, a 1/4"NPT gauge port, and a manual shutoff valve.
8118P

Features:
  • Designed as a filler valve for LP-Gas with upper check and manual shutoff.
  • Excess flow valve allows for maximum filling rates regardless of the length of the coupling the valve is installed in.
  • Excess flow seat us fully contained in the tank coupling for maximum protection in the event of external damage to the valve.
  • Breakaway groove protects the ACME in the case of a drive-away with the filler hose still connected.
  • V-ring spring loaded stem assembly requires no repacking of field adjustment.
  • Plugged ¼" NPT boss allows for a pressure gauge to be installed.
  • The one-inch outlet port plugged.

CLICK HERE for Product Page 

DOT Regulatory REMINDER 
Changes to Shipping Paper Requirements Effective January 1, 2013

A DOT rule became effective January 1, 2013.  The rule adopted nearly six years ago regards the shipping paper basic description.  Amazingly, the rule didn't add or require new information, it simply changed the order of the basic description in the shipping paper sequence to harmonize with international standards.

 

The previous shipping paper order sequence was: Shipping name, Hazard class, ID number, Packing Group (note that there are no packing group requirements for propane).

 

The new shipping paper order sequence that became effective January 1, 2013 simply moves the ID number to the top so that the new order would be:

  • ID number
  • Shipping name
  • Hazard class
  • Packing Group
If you have not replaced your old style shipping papers with new ones; they can be ordered from GEC.  The part numbers for the NEW STYLE shipping paper are:
  • V-83 for Shipping Paper for Bulk Truck
  • V-83-CYL for Shipping Paper for Cylinder Trucks

Shipping paper  

It's Cold & You are doing a lot of Leak Tests;  Do them More Efficiently!
Presto-Tap Universal Service Tech Kit
Presto-Flexible Presto-Tap announces a comprehensive technician kit designed to be carried by drivers and service personnel to perform NFPA leak testing on all stages of a gas system.  The Kit includes all four test gauges (300 psig, 30 psig, 5 psig, & 0-35 inches water column) along with various barbs, adapters, a universal flex hose w/ bleeder assembly, all packaged in a 12 inch gate mouth bag with internal and external pockets.  Utilized for leak testing at pressure locations where a PRESTOTAP® LDS (Leak Detection System) products have been permanently installed - especially helpful for testing at underground tank installations.

Presto-Tap USK

The Universal Service Tech Kit includes the following: 

  • 6800 KG W/Adapter - 300# Ambient Temperature gauge used for Leak Testing at tank pressure with Presto Tap® pigtails, TPF fittings and RegO® "Ready to Go" series valves.
  • PT30 KG W/Adapter - 30# Gauge for determining first stage regulator lock up and flow along with leak testing.
  • PT-5# KG W/Adapter - 5# gauge for determining lock up and flow on Two Pound Systems.
  • PT-OZ KG W/Adapter - 0-35 inch water column gauge for measuring second stage regulator lock up and flow along with low pressure leak testing.
  • MHA Kit - Adapter used to facilitate use of master manometers (water manometer) or magnehelic gauges.
  • 3/16" Allen/Hex Key - for plug removal in regulators.
  • Universal Flex Hose - 36" flexible hose with gauge bleeder and adapters utilized to universally connect with all gauging equipment above and Presto Tap LDS2000/RV product installed in the system.
  • LDS2000/RV - (6) UL Listed fittings with #54 orifice legal installed at any point in the system.
  • Kit Bag - 12" Tool Denier Nylon Tool bag with 6 outer and 15 inner pockets.

The kit also includes laminated suggested leak testing procedures from NFPA 54 Annex D.

 

 CLICK HERE for the Presto-Tap Universal Service Kit flyer 

 

"TECH Topic"
Motor Thermostats & Crankcase Heaters
Make Sure You Hook Them Up. 

Protect your Motor Investment &

Protect your Motor Warranty

  

If you are making investments in new pumps and motors for the Autogas market; make sure you are wiring your motors in accordance with the electrical codes.  Motors 2 HP and over require thermal overload protection.

 

Have you ever looked inside an electric motor junction box and noticed extra wires, sometimes yellow, grey or brown? These are probably additional protection options for your motor; such as thermostats and crankcase heaters.  

  

In addition to the thermal overload protection (usually provided within manual and magnetic starters) some motors utilize internal thermostatsThese thermostats are designed to protect motors from internal overheating due to undersized service wiring, overloaded conditions or even low voltage issuesBUT, for the thermostats to function they must be utilized.  For a thermostat to properly function it must be wired into the control circuit of a magnetic starter with either relays or a momentary start/stop switch.  When the thermostats sense an overheat situation they open the control circuit, thus dropping out the magnetic starter relay and causing the motor to shut-down prior to being damaged.  We find many times on motors returned for warranty issues that the installer has failed to utilize the protective thermostats, and in some cases voiding the motor warranty.

  

Another protection option we see quite regularly on LPG motors is internal motor crankcase heaters.  These heaters are NOT to be confused with overload heaters you find in starters.  Since LPG pump motors are cycled On & Off quite often in cold environments during the winter, they generally experience condensation of humidity inside the motor housing which occasionally leads to a failed motor due to either short-circuiting or freezing of the moisture on cold nights/days locking up the motor.  In other words, when cold motors are started and stopped repeatedly, they warm up and the cold humid air condenses to moisture inside the motor. 

 

To prevent moisture from condensing inside the motor; motor manufacturers have installed heaters inside the housing to keep the motors warm and dry when not running.  This prevents the buildup of condensation inside the motor.  But, just as the thermostats discussed above will not function if they are not connected; NEITHER will the HEATERS protect a motor from condensation if they are not connected to a power source.  The heaters must be connected to a separate power source to function when the motor is NOT running.  They are usually wired through a N/C (normally closed) relay on a magnetic starter so they are powered when a motor is NOT running; and shut off during the time the motor is running.

 

If you have additional questions on electric motor thermostats or crankcase heaters; contact your GEC sales representative, customer service representative or project manager. 

 

Laughing
Joke of the Month:  

 

 

"Cold" is a relative term

Use the handy list below to overcome the confusion.

 

Degrees (Fahrenheit)

65 - Hawaiians declare a two-blanket night

60 - Californians put on sweaters (if they can find one)

50 - Miami residents turn on the heat

45 - Vermont residents go to outdoor concerts

40 - You can see your breath  

   - Californians shiver uncontrollably  

   - Minnesotans go swimming

35 - Italian cars don't start

32 - Water freezes

30 - You plan your vacation to Australia

25 - Ohio water freezes

   - Californians weep pitiably

   - Minnesotans eat ice cream

   - Canadians go swimming

20 - Politicians begin to talk about the homeless

   - New York City water freezes

   - Miami residents plan vacation further South

15 - French cars don't start

   - Cat insists on sleeping in your bed with you

10 - You need jumper cables to get the car going

5 - American cars don't start

0 - Alaskans put on T-shirts

-10 - German cars don't start

    - Eyes freeze shut when you blink

-15 - You can cut your breath and use it to build an igloo

    - Arkansans stick tongue on metal objects

    - Miami residents cease to exist

-20 - Cat insists on sleeping in pajamas with you

    - Politicians actually do something about the homeless

    - Minnesotans shovel snow off roof

    - Japanese cars don't start

-25 - Too cold to think

    - You need jumper cables to get the driver going

-30 - You plan a two week hot bath

    - Swedish cars don't start

-40 - Californians disappear

    - Minnesotans button top button

    - Canadians put on sweaters

    - Your car helps you plan your trip South

-50 - Congressional hot air freezes

    - Alaskans close the bathroom window

-80 - Hell freezes over

    - Polar bears move South

    - Viking Fans order hot cocoa at the game

-90 - Lawyers put their hands in their own pockets


For Specific Product or Service Questions please contact one or our Customer Service Warehouses below:

Atlanta, GA

(800) 241-4155         

Dallas, TX

(800) 821-1829

Fayetteville, NC

(800) 447-1625

Houston, TX

(800) 334-7816

Indianapolis, IN

(800) 241-1971

Kansas City, MO

(800) 821-5062

Little Rock, AR

(800) 643-8222

Orlando,  FL

(800) 821-0631

Richmond, VA

(800) 368-4013

St. Louis, MO

(800) 423-4685


Sincerely,
GEC e-Newsletter
Gas Equipment Co., Inc
In This Issue
RegO 8118P
DOT Regulatory Reminder: Shipping Papers
Presto-Tap Universal Service Tech Kit
TECH Topic: Motor Thermostats & Crankcase Heaters
Coro-Flo Maintenance Instruction
HEATSTAR Vent-Free Heater SPECIAL OFFER
Autogas Special
Join Our Mailing List
Quick Links
 
 
 
Register Now to receive the GEC e-Newsletter

Corken On-Line
 Coro-Flo Pump Maintenance

Instruction

Gas Equipment is providing a web link to assist our customers with their Corken Coro-flo pump repairs.

 

This link will take you directly to the Corken web page dedicated to Step-by-Step instruction on maintenance so you can SEE with slides and text, how to disassemble, repair and reassemble your Coro-flo pumps.

 

We hope you find this information helpful but we are always there to help guide you through the process if you should require additional help.

 

Our Sales Representatives are factory trained and can conduct FREE on-site training for your technicians.  Just contact them to schedule a time that is convenient for you. 

 

HEAT STAR Vent-Free Heaters 
HeatStar
AUTOGAS
DISPENSER
SPECIALS

HDP Autogas
 & Cylinder
Dispenser
Special
$ 9,649.44
DCL51DP.LGL156.1PH

Product Description 

 

DCL51DP.LGL156.1PH Modified Dispensing Cabinet package, Aluminum diamond plate exterior 51"H x 47-1/2"W x 39-1/2"D, Includes BLACKMER Model LGL156A High Differential Pressure Pump, 5HP 1PH EX Proof Motor and On/Off Switch, By-Pass Valve, Inlet & Outlet flanges, gaskets, studs & nuts, 1" ITRON Meter and All Inside Cabinet Piping, Autogas & Cylinder filling hoses, Tank to Pump plumbing Kit, Cylinder Purge Kit, Pneumatic Actuator Kit and Electrical Conduit Kit.

  

CFT PRO-2100 Dispenser  

$6,906.40  

as spec'ed

 

Pro2100 

 

CFT PRO-2100 Mini-Skid Package

$13,832.00 

as spec'ed

2100 Mini Skid

Includes:

PRO-2100 Dispenser

Mini-Skid System

Piping from pump to dispenser including bypass valve

DLF-075 Corken HDP Autogas pump with 7.5HP-3PH motor

 

#SKD000210077 

#P2100T0S0  

 

 CLICK HERE to View the CFT Catalog  

 

Click Here to View the GEC Dispenser Catalog including Cylinder & Autogas Offerings 

Do you have associates who would like to receive the e-Newsletter?   

 
 

Inet Specials

Save with Internet Specials

Visit www.gasequipment.com and shop online at the "GEC Virtual Warehouse" and take advantage of several Internet Specials. 

ALL YOU HAVE TO DO IS REGISTER FOR A WEB ORDER ENTRY (WOE) ACCOUNT WITH GEC*.  You'll be issued a confidential user I.D. and password that will allow you to order on your schedule.

Click "Register for Online Ordering" to get started.

 

*All registrants must have a current account with GEC in good standing before the WOE account can be activated.

 

For a copy of the GEC Solutions introducing our CLICK, SEARCH, BUY, MANAGE edition of our Virtual Warehouse email your request to

e-newsletter@gasequipment.com

Online Specials are changed regularly, check back periodically for new offerings!