July 2015
Dear    ,

It's been a while since we sent out our last newsletter, so thank you for your patience! Are you enjoying your summer?

Did you know that we now have a Facebook page? CLICK HERE to like our page. Our newsletter will also be posted on that page.

It is time for our Annual Education Survey. We would love it if you would take about 5 minutes and fill it out by August 31st. All responses received by this date will be entered into a drawing for a "Neoss Prosthetic Tray Kit". An e-mail will be sent out announcing the winner on September 4th. 
If, for any reason you do not get a confirmation of your survey being submitted after completing it, simply e-mail Marketing and say "I completed the survey" in the subject line and your name. 

Please send an e-mail to Marketing if you would like to see a specific topic featured, if you have a case that you would like to share with the subscribers, or a testimonial. 

Thank you for reading.

Pia
Pia Jansson
Activity Directory, Neoss Inc.
In This Issue
Product News
NeoGen™ Ti-Reinforced Membrane

Neoss have announced the pre-launch of NeoGen™, a new generation of titanium reinforced membrane.

We are proud of our company's continued focus on research and development, and have developed the NeoGen™ membrane through a close partnership with leading experts within the GBR field.

NeoGen™ Ti-reinforced membrane combines the unique handling and tissue interaction properties of expanded PTFE with the enhanced barrier function of dense PTFE.

Following on from the successful prelaunch at the IDS in Cologne, Germany, March 10-14, we are happy to announce the pre-launch of NeoGen™ Ti-reinforced membrane to the American market.

Please talk to your local representative about our current offers or call Customer Service at 866-626-3677.

To view the NeoGen™ brochure CLICK HERE.


Assortment

Art. No.Description
64010NeoGen™ Ti-Reinforced Membrane - S I (Small Interproximal, 29x14 mm)
64011NeoGen™ Ti-Reinforced Membrane - M I (Medium Interproximal, 30x19 mm)
64012NeoGen™ Ti-Reinforced Membrane - L I (Large interproximal, 36x21 mm)
64013NeoGen™ Ti-Reinforced Membrane - M (Medium 32x22 mm)
64014NeoGen™ Ti-Reinforced Membrane - L (Large, 34x25 mm)

Prosthetic Tray
The Prosthetic Tray has a unique design which exemplifies Intelligent Simplicity.
 
  • Fits in the palm of your hand, easy to hold and open
  • Low profile with rigid non-skid base
  • Easy access to instruments
  • Dedicated to hold and store Neoss restorative instruments

Assortment

Item No.Description
51180Prosthetic Tray (excluding instruments)
51181Prosthetic Instrument Kit (available fall of 2015)
Includes
51180 - Prosthetic Tray
51121 - Ratchet
51139 - Screwdriver Machine 22 mm
51140 - Screwdriver Machine 32 mm
51141 - Screwdriver Manual 15 mm
51126 - Manual Handle
Neoss® Guide Kit
Neoss® Guide Kit provides a fully guided solution for surgical preparation using existing Neoss drills with subsequent placement of Neoss Implants Ø3.5 - Ø4.5 mm. Case planning is made in your existing planning software and the guide is manufactured by your guide provider. 

CLICK HERE to view or download the flyer

Compatible Systems
 Software Company Planning Software Guide
 3D Diagnostix Planning service, no software  purchase necessary 3DDX Guide
 nSequence Maven Pro nSequence Surgical Guide
 Sirona  GALILEOS Implant,
 SICAT Implant
 SICAT Surgical Guides
 Anatomage Invivio 5 Anatomage Guide
 3shape Implant Studio Implant Studio
 Materialise Simplant Universal Guide
 (Nobel Biocare)
 Dental Wings Codiagnostix Codiagnostix Guide
 Nobel Biocare NobelClinician Software* NobelGuide®
 3Diemme 3Diagnosys® RealGuide™

* Use Replace RP 4.3 as reference implant and consider dimensional differences.
Upcoming Events
Exhibits
 Org./Mtg Name
Neoss
Booth #
 Date(s)
 Location
 ICOI /ICOI Pros  Symposium
314
 August 14-16, 2015 Marriott Marquis
 San Francisco, CA
 ACP
312
 October 22-23, 2015 Renaissance Orlando SeaWorld
 Orlando, FL
 AAID
201
 October 22-24, 2015 Caesars Palace
 Las Vegas, NV
 AAP
624
 November 15-17, 2015 Gaylord Palms Hotel & Conv. Ctr
 Kissimmee, FL
 GNYAP
N/A
 December 4-5, 2015 Jazz at Lincoln Center
 New York, NY
 AO
1136
 February 18-20, 2016 San Diego Conv. Ctr
 San Diego, CA
 Quintessence
TBD
 June 16-18, 2016 Marriott Copley Place
 Boston, MA


Education
Organization
 Topic
 Date
 Location
 NYIADS Extractions and Grafting for the  General Dentist September 30, 2015 Melville NY
 NYIADS Immediate Loading of the  Edentulous Arch October 14, 2015 Melville, NY
 NYIADS Guided Surgery: Computer  Guided Implant Dentistry November 18, 2015 Melville, NY
 NYIADS An Intensive 3-day Basic  Implant Surgery Course December 3-5, 2015 Melville, NY

Clinical Case
Neoss Implant and TiBase
- Case courtesy of Dr. Glen Harvey, Toowong Village Dental, Australia

Clinical Situation
Root fracture with hopeless prognosis

Neoss Straight Ø5 x 9 mm implant placed 3 months after tooth removal. Osteotome sinus lift.


Scanning
Model based scan. Implant level impression and working cast with removable gum slip.

Neoss TiBase Abutment comes with laboratory screw and Crystaloc™ abutment screw. Correct scan body is supplied from Sirona™ (in this case white scan body for Cerec Bluecam L 64 31 303).

Model based impression (CEREC AC Bluecam). TiBase and scan body in place

Design
Design in inLab. Virtual model created after scanning gingival mask overlaid. TiBase virtually seated (TiBase reference in the software for Neosss TiBase N is NB B 3.4 L), restoration axis determined and gingival margin determined.

Crown designed

Margin for junction of crown and abutment established using gingival mask as a guide.

Design split into abutment and crown.
Manufacturing
Customized Zirconia abutment ready to mill (use Sirona block inCoris® ZI meso L or IPS e.max® CAD CEREC®/inLab MO A14 (L)/ A16 (L) by Ivoclar Vivadent®).

IPS e.max® CAD crown ready to mill.

Assembling
Sandblasted TiBase (using the Protection Replica), sintered abutment and non-crystallised e.max® crown.
e.max® CAD crown crystallized and 
used to abutment with fusing ceramic (IPS e.max® CAD Crystall./Connect). 

TiBase is cemented to Zirconia abutment with opaque resin cement. 
Neoss Crystaloc™ screw in place.


Final Result
Radiograph to check seating of abutment. Platform shift created by the difference between the implant diameter and the prosthetic platform is clearly visible.

Restoration torqued to 32Ncm. Screw access restored with composite resin.
New/Updated PDF Files
Available for download


Intelligent Simplicity  |  www.neoss.com
Neoss Inc. 21860 Burbank Blvd. #190, Woodland Hills, CA 91367 | Ph. (818) 432-2600  or (866) 626-3677|