Website Banner
Week 29 Quality Report



White Horse Laboratories has been publishing our Weekly Quality Reports since 2009, which are a listing of the devices that have had over 5% lot failure in electrical testing or the buyer has rejected the lot following results of inspection methods

While this list does not imply that the balance of devices within a lot are defective, and is not exhaustive (for example, a 5% failure rate may be too high or some buyers may accept devices in a physical condition that others would not), it is intended to an indicator as to what is going on in the market and is a reminder to be aware of the risks of sourcing without adequate quality control measures in place.

Week 29 

Inspection Accept 

83%

 

Electrical Testing Pass

67%

This Week in The Lab...

                                   
White Horse Laboratories' Quality Report

Week 29 Quality Report

Substandard Parts List
                           

STMicroelectronics ST72251G2MCLKNTR (Date Code 630) - 6% Failure Rate - Short pins and broken protection diodes.


Texas Instruments DAC712UB (Date/Lot Code 39AR6ST) - 67% Failure Rate - Low Vref and Vout.

 

Innovasic IA188ES-PQF100I-R-03 (Date Codes 1314, 1322, 1327, 1337, 1344, and 1350) - 19% Failure Rate - Open and shorted pins with broken protection diodes.

 

Xilinx XC5VFX30T-2FFG665I (Date Code 1441) - 26% Failure Rate - Program error.

 

Freescale MPC823ZQ66B2T (Date Code 1339) - 100% Failure Rate - Pins P1 and P10 are connected and should be no connects (NC), see below.

 

Altera EPM7512AEF1256-10N (Date Code 1331) - 33% Failure Rate - Program Error.

 

Analog Devices ADA4091-2ARZ (Date Code 1431) - 100% Failure Rate - No output and overheated.

 

STMicroelectronics ST72251G2MCLKNTR (Date Code 617) - 10% Failure Rate - Broken protection diodes.

 

Murata GRM188R60J475KE19D (Lot Code PT266) - 29% Failure Rate - Low capacitance.

 

MPC823ZQ66B2T - Pins P1 and P2 should be NC (no connect) but show they are connected.
                                                      
Weekly Report Archives
Tune in thru WeChat
Follow Us on WeChat
Substandard Parts Lists dating back to 2009


White Horse has been publishing Weekly Quality Reports since 2009. Now we open those archives to you.

 

Simply click on the Weekly Quality Report page on our website and then click the "View our Archive" button to see each posting from 2009 thru 2015.


We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories
Notes:

1. Statistics are calculated as a percentage of all lots dis-positioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.