Website Banner
Week 27 Quality Report



White Horse Laboratories has been publishing our Weekly Quality Reports since 2009, which are a listing of the devices that have had over 5% lot failure in electrical testing or the buyer has rejected the lot following results of inspection methods

While this list does not imply that the balance of devices within a lot are defective, and is not exhaustive (for example, a 5% failure rate may be too high or some buyers may accept devices in a physical condition that others would not), it is intended to an indicator as to what is going on in the market and is a reminder to be aware of the risks of sourcing without adequate quality control measures in place.

Week 27 

Inspection Accept 

73%

 

Electrical Testing Pass

64%

This Week in The Lab...

                                   
White Horse Laboratories' Quality Report

Typhoon Linfa
Signal 8 Raised in Hong Kong at 4:40pm Local Time

TyphoonThe Hong Kong Observatory issued the Typhoon #8 signal at 4:40pm following announcements to that affect starting much earlier in the afternoon.

While we were able to get most shipments out before courier closed, there were a couple yet to be collected which couriers delayed pickup until the typhoon signal was reduced to 3 or lower.

Please keep an eye on your tracking numbers as, even if courier did pick up, that does not confirm flights left Hong Kong on schedule.

We expect our Hong Kong team to return to work on Friday morning at regularly scheduled time. Our Shenzhen operations have not been affected by the typhoon.

Week 27 Quality Report

Substandard Parts List
                           

Harris CA3020A3 (Date Code 9924) - 86% Failure Rate - Low or no switching and broken pins.


ON Semiconductor MBR0530T1G (Date Code not marked or labeled) - 28% Failure Rate - High forward voltage, Vf. 

 

Analog Devices OP207AY (Date Code 0041) - 67% Failure Rate - No output from an internal short-circuit which pulled down the input signal.

 

STMicroelectronics L9162 (Multiple Date Codes) - 19% Failure Rate - Frequency channels not switching, no CAN bus switching, and incorrect pin out.

 

Analog Devices AD595CD (Date Code 0430) - 43% Failure Rate - Readings above and below the 1% C of converted output.

 

Xilinx XC4VFX40-11FFG672C (Date Code 0237) - 20% Failure Rate - Cannot download, failed JTAG test.

 

 

AD595CD Failure for High Output at temperature variation.
                                                      
Weekly Report Archives
Tune in thru WeChat
Follow Us on WeChat
Substandard Parts Lists dating back to 2009


White Horse has been publishing Weekly Quality Reports since 2009. Now we open those archives to you.

 

Simply click on the Weekly Quality Report page on our website and then click the "View our Archive" button to see each posting from 2009 thru 2015.


We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories
Notes:

1. Statistics are calculated as a percentage of all lots dis-positioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.