While this list is not exhaustive (for example, a 5% failure rate may be too high or some buyers may accept devices in a physical condition that others would not), it is intended to an indicator as to what is going on in the market and is a reminder to be aware of the risks of sourcing without adequate quality control measures in place.

Week 22 

Inspection Accept 

76%

 

Electrical Testing Pass

83%

This Week in The Lab...

                                   
White Horse Laboratories' Quality Report

Week 22 Quality Report

Substandard Parts List
                           

Texas Instruments TMS320F243PGEA (Date Code 0535) - 11% Failure Rate - Shorted pins.

 

Xilinx XCE0104-4FF1152C109002 (Date Codes 1021, 1029, and 1035) - 13% Failure Rate - Program error and no output.

 

Xilinx XC9536-10PC44C (Date Code 1334) - 14% Failure Rate - Program error (version on failed pins is "0000").

 

Samsung LTM170E8-L01 (Date Code not marked or labeled) - 17% Failure Rate - Horizontal line on display panel.


 

Refurbished and Remarked Texas Instruments TMS320F243PGEA - Shorted pins failures consistent with refurbished devices.
                                                      
Weekly Report Archives
Tune in thru WeChat
Follow Us on WeChat
Substandard Parts Lists dating back to 2009 Now Available


White Horse has been publishing Weekly Quality Reports since 2009. Now we open those archives to you.

 

Simply click on the Weekly Quality Report page on our website and then click the "View our Archive" button to see each posting from 2009 thru 2015.


We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories
Notes:

1. Statistics are calculated as a percentage of all lots dis-positioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.