Since 2009, White Horse Laboratories has been publishing our Weekly Quality Reports, which is a listing of the devices that have had over 5% lot failure in electrical testing or the buyer has rejected the lot following results of inspection methods

While this list is not exhaustive (for example, a 5% failure rate may be too high or some buyers may accept devices in a physical condition that others would not), it is intended to an indicator as to what is going on in the market and is a reminder to be aware of the risks of sourcing without adequate quality control measures in place.

Week 15 

Inspection Accept 

81%

 

Electrical Testing Pass

79%

This Week in The Lab...

                                   
White Horse Laboratories' Quality Report

Holiday Notice
Labor Day is Awesome!
May 1 - Labor Day Holiday

Plenty of notice to plan your supply chains accordingly...

Our Hong Kong facility will be closed on Friday, May 1, for the International Labor Day (also called May Day) holiday. We will return for our regular half day Saturday on May 2.

Our China operations will be closed on Friday, May 1, through Sunday, May 3, and resume regular operations on Monday, May 4.

Weekly Report Archives
Tune in thru WeChat
Follow Us on WeChat
Substandard Parts Lists dating back to 2009 Now Available


White Horse has been publishing Weekly Quality Reports since 2009. Now we open those archives to you.

 

Simply click on the Weekly Quality Report page on our website and then click the "View our Archive" button to see each posting from 2009 thru 2015.


Week 15 Quality Report

Substandard Parts List
                           

Siemens TDA4718B (Date Code 837) - 17% Failure Rate - Broken protection diodes.

 

Xilinx XC4044XLA-09HQ160I (Date Code 0521) - 11% Failure Rate - Program error and no output.

 

STMicroelectronics STPS1H100A (Date Code not marked or labeled) - 35% Failure Rate - High Forward Voltage, Vf, and Reverse Current, Ir. 

 

ALI M6117D (Date Codes 1117, 1133, and 1145) - 91% Failure Rate - Open and shorted pins with broken protection diodes.

 

ALI M6117D Failures - Unlike common Curve Trace tests, our Pin Verification test covers all pins, not only a select few, which is more likely to catch damage such as this from prior use, salvaging, and refurbishing.
                                                      
We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories
Notes:

1. Statistics are calculated as a percentage of all lots dis-positioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.