Website Banner

Week 3 Report

 

Inspection Accept

71%

 

Electrical Testing Pass

67%

This Week in The Lab...
Week 3 Summary
Substandard Parts List

                                   
White Horse Laboratories' Quality Report

Week 3 Summary                                                                        

 

Week 3 saw results we hope will become the pattern, or at least the norm, throughout 2015 with Electrical Testing and Inspection both posting gains over the previous week's results.

 

Electrical Testing climbed from 60% in Week 2 to 67% in Week 3 and Inspection yields surging to 71% in Week 3 after falling to 44% in Week 2.

 

A total of five new part numbers were added to the Substandard Parts List, with one posting a 100% failure rate.

Week 3 Quality Report


Substandard Part Listing 

 

STMicroelectronics L5972D - (Date Code 1423) - 24% Failure Rate - High output voltage (Vout). 

 

Simtek STK14CA80N45 - (Date Code 901) - 13% Failure Rate - Program & Verify error.

 

Avago HCPL-4504-000E - (Date Code not marked or labeled) - 55% Failure Rate - No output response.

 

Analog Power AM4935P (Date Code not marked or labeled) - 67% Failure Rate - High Rds(on).

 

Renesas UPA2735GR-E1-AT (Date Code not marked or labeled) - 100% Failure Rate - High Rds(on) at two gate voltage levels. 

Avago HCPL-4504-000E high failure rate for no output response.
Notes:

1. Statistics are calculated as a percentage of all lots dis-positioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories