Website Banner

Week 50 Report

 

Inspection Accept

89%

 

Electrical Testing Pass

75%

This Week in The Lab...
Week 50 Summary
Substandard Parts List

                                   
White Horse Laboratories' Quality Report

Happy Holidays! Our Hong Kong facility will be closed on the 25th and 26th of December for Christmas and Boxing Day holidays and again on January 1st for New Year's Day. Our China operations will only be closed on New Year's Day.

 

Week 50 Summary                                                                        

 

We will be catching up on the listings for Weeks 27 thru 35 in two consolidated reports to be published over the next two weeks.

 

Week 50 saw an improvement in both Electrical Testing and Inspection yields. Maybe someone figured out the quality parts sell better?

 

Electrical Testing yields weighed in at 75%, up from 65% in Week 49, and Inspection yields leapt to 89% from a meager 50% in Week 49.

 

There were just new devices added to the substandard parts list from Week 49, one of which had a 100% failure rate. 

Week 50 Quality Report


Substandard Part Listing 

 

Integrated Device Technology IDT7026L25GM - (Date Codes 0723 and 0726) - 29% Failure Rate - Signal distortion. 

 

Burr Brown OPA4277UA/2K5 - (Not marked or labeled) -

100% Failure Rate
The output had no gain and the input signal was pulled low.

 

 

Burr Brown OPA4277UA failed for no gain of output.
Notes:

1. Statistics are calculated as a percentage of all lots dis-positioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories