Week 22 Report

 

Inspection Accept

74%

 

Electrical Testing Pass

64%

This Week in The Lab...
Week 22 Summary
Substandard Parts List

                                   
White Horse Laboratories' Quality Report

Week 22 Summary                                                                        

 

Electrical Testing yields broke their pattern of stabilization in Week 22 while Inspection yields held steady.

 

Testing yields had been holding at 70-75% for nearly two months, but dropped sharply to 64% in Week 22, with eight part numbers being added to the substandard part list. None of the parts had a 100% failure rate.

 

Inspection yields held steady at 74% for a second consecutive week.

Week 22 Quality Report


Substandard Part Listing 

 

Avago Technologies HCPL-7800A-000E (Date Codes 1114 and 1137) - 64% Failure Rate - High gain.

 

Xilinx XC4VLX4010FFG668C (Date Codes 1103 and 1137) - 46% Failure Rate - Program error and shorted pins (VCCIO shorted to GND).

 

Xilinx XC9536-10VQG544C (Date Code 1045) - 9% Failure Rate - Program error (version is "0000").

 

STMicroelectronics M25PX32-VMP6E (Date Code not marked or labeled) - 8% Failure Rate - Blank-check error (previously programmed) and poor pin contacts.

 

Altera EP2C8F256C8N (Date Code 1345) - 36% Failure Rate - Program error and no output.

 

Altera EP2SGX90EF1152C5N (Date Code 0921) - 6% Failure Rate - Program error and detached heat sink.

 

Atmel AT90CAN128-16MU (Date Code 1235) - 10% Failure Rate - Poor pin contacts.

 

SGS-Thomson Microelectronics VN02NE (Date Code not marked or labeled) - 9% Failure Rate - No output.

Avago Technologies HCPL-7800A-000E Isolation Amplifier 64% Failure Rate for high Gain.

Measured at >0.989V, specification is 0.792 - 0.808V

Notes:

1. Statistics are calculated as a percentage of all lots dis-positioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories