Website Banner

Week 19 Report

 

Inspection Accept

48%

 

Electrical Testing Pass

73%

This Week in The Lab...
Week 19 Summary
Substandard Part Listing

                                   
White Horse Laboratories' Quality Report

Week 19 Summary                                                                        

 

After both Electrical Testing and Inspection yields posted gains in Week 18, they both suffered lapses in Week 19.

 

Testing yields dipped back to 73% in Week 19 after climbing to 74% in Week 18 and have been relatively stable at 70-75% for the past six weeks.

 

After three straight weeks of improvement, Inspection results collapsed to just 48% in Week 19 after working hard for three weeks to climb their way up to 76% in Week 18.

 

There are five part numbers with electrical failure rates of over 5% on the list this week, one of which had a 100% failure rate.

Week 19 Quality Report

  

Substandard Part Listing

 

National Semiconductor LM4140CCM-1.0  (Date Code not marked or labeled) - 6% Failure Rate - Readings beyond the specified limits.

 

ST Microelectronics VN5770AKPTR-E (Date Codes 348&349) - 78% Failure Rate - Low output and high supply current.

 

Infineon IPP70N10SL-16 (Date Code not marked or labeled) - 100% Failure Rate - High Vgs(th).

 

STMicroelectronics ST72T141K2M6  (Date Code not marked or labeled) - 8% Failure Rate - Failed loading program.

 

Altera EPM7160STC100-10N (Date Code not marked or labeled) - 75% Failure Rate - Program error. 

Infineon IPP70N10SL-16 - 100% failure for High Vgs(th)
Notes:

1. Statistics are calculated as a percentage of all lots dis-positioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories