Website Banner

Week 5 Report

 

Inspection Accept

65%

 

Electrical Testing Pass

59%

This Week in The Lab...
The Year of the Horse Begins
Week 5 Summary
Substandard Part Listing
                                           
                                   

China Coming back to Life after the Spring Festival
2014 - The Year of the Horse

Many manufacturers resumed operations on Friday the 7th and will continue to ramp up as their full workforces return from the holiday break. 

 

Service and trading companies, including the electronics trading markets, largely resumed operations today and will also continue to ramp up as staff return from their journeys to all parts of China, and internationally.

 

Hong Kong officially returned to work on Tuesday the 4th, albeit not at full scale as many took advantage of the country-wide shutdown of their huge neighbor.

                            
White Horse Laboratories' Quality Report

Week 5 Summary                                                                        

 

Electrical Testing yields dipped from 76% in Week 4 to 59% in Week 5 on relatively light activity as the Chinese New Year holiday approached..

 

Inspection yields edged forward again to 65% in Week five, up from Week 4's 62% in Week 4, marking a third straight week of improvement after starting 2014 with an abysmal 28%.

 

There were six lots with higher than a 5% failure rate, on of which was 100% with incorrect pin assignments.

Week 5 Quality Report

 

Substandard Part Listing

 

Infineon Technologies KTY11-6  (Date Code not marked or labeled) - 40% Failure Rate - Low resistance.

 

Maxim DS1267-010  (Date codes 0005, 0013, 0028, and 0042) - 16% Failure Rate -High resistance.

 

Xilinx XC9572-10PC84I (Date Codes 0209 and 0215) - 8% Failure Rate - Program error and no output.

 

STMicroelectronics ST72T141K2M6 (Date Code not marked or labeled) - 8% Failure Rate - Failed loading program.

 

Cirrus Logic ISP1160BM/01 (Date Code 1239) - 100% Failure Rate - Incorrect pin-outs.

 

ST Microelectronics STY60NM50 (Date Code not marked or labeled) - 24% Failure Rate - Low breakdown and high leakage.

Cirrus Logic ISP1160BM/01  - Pins 23, 30, 31, 36, 41, 48, and 49 are Non-Connects (NC). Should be pins 26, 30, 31, 36, 38, 41, 48, 49, and 61.
Notes:

1. Statistics are calculated as a percentage of all lots dis-positioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories