Inspection Accept

57%

 

Electrical Testing Pass

63%

This Week in The Lab...
November 2012 (Weeks 45-48) Summary
Substandard Part Listing
                                      
                                   
White Horse Laboratories' Quality Report

December 2013 (Weeks 49-52) Summary                                                                        

  

And to finish off 2013, this is the final report for the year 2013, summarizing December. Please note that the last report was for Weeks 45-48 of 2013, not 2012.

 

In Week 49, Electrical Testing yields held steady at 84% in Week 49 and then plummeted to 50% in Week 50, edged up to 62% in Week 51, and then finished 2013 at 73% in Week 52, averaging 63% for the month.

 

There were 14 lots with higher than a 5% failure rate, only one of which was 100% which generally indicates outright counterfeit devices.

 

Inspection yields also held steady at about 67% in Week 49 and then dropped to just 48% in Week 50, inched forward to 50% in Week 51, and then leapt to 72% in Week 52 to finish off the year. Inspection yield averaged 57% for the period.

Weeks 49-51 Quality Report

 

Substandard Part Listing

 

Aili M6117D (Date Codes 0607 and 0613) - 7% Failure Rate

- shorted pins and bad protective diodes (used/refurbished).

  
Linear Technology LTM4620AEV#PBF (Date Code 1239) - 33% Failure Rate - no output or high input current.

 

Mitsubishi CM200DY-28H

High Ices, 100% Failure Rate

Mitsubishi CM200DY-28H(Date Code not marked or labeled) - 100% Failure Rate - High Ices.

 

Intel LXT388LE.B2 (Date code not marked or labeled) - 20% Failure Rate - bad protective diodes (used/refurbished).

 

Motorola MC68B21CP (Date Codes 0415, 0440, 0442, and 0507) - 11% Failure Rate - bad protective diodes (used/refurbished).
  
Micron Technology MT48LC4M16A2P-75:G (Date code 1020) - 39% Failure Rate - Open pins.

  

Epson SPG8650A (Date code 0625) - 30% Failure Rate - no oscillation.

 

Texas Instruments SMJ55161-80GBM (Date code 0918) - 26% Failure Rate -open pins and broken protective diodes.

 

Xilinx XC2VP20-6FF1152I (Date Codes 1229 and 1205) - 77% Failure Rate - program error.

 

STMicroelectronics ST72T141K2M6 (Date Code not marked or labeled) - 7% Failure Rate - failed loading program.

 

Analog Devices AD8031ARTZ (Date Code 1248) - 8% Failure Rate - output distortion.

  
Apex Microtechnology PA12H (Date Code not marked or labeled) - 25% Failure Rate - No output.

 

Xilinx XC95144-10TQG100I (Date Codes 0941 and 1121) - 19% Failure Rate - program error.

 

Texas Instruments INA111AU (Date code not marked or labeled) - 9% Failure Rate - high negative offset.
Notes:

1. Statistics are calculated as a percentage of all lots dis-positioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories