Website Banner

Week 38 Report

 

Inspection Accept

57%

 

Electrical Testing Pass

61%

This Week in The Lab...
Weeks 38 Summary
Substandard Part Listing
                               
                                   
White Horse Laboratories' Quality Report
Week 38, 2013

Weeks 38 Summary                                                                                                          

  

Electrical Testing halted its descent into the abyss, landing at 61% in Week 38 after crashing to 54% in Week 37.

 

Two of those devices had a 100% failure rate, indicating outright counterfeits.

 

Inspection results staged a more staunch resistance to its plummeting average, recovering to 57% in Week 38 after falling to 27% and hitting the rocks in Week 37.

Week 38 Quality Report

 

Substandard Part Listing

 

Kemet T495D107K010ATE080 - 100% Failure for high ESR. Spec is <80mΩ, measurement was 131.

Xilinx XC9536-10VQ44C (Date Code 1103+) - 14% Failure Rate - Program error.

 

Xilinx XC9572-10TQG100C (Date Code 1137) - 6% Failure Rate - Program Error.

 

Altera EP2S60F1020C5N (Date Code 831) - 100% Failure Rate - No output and program error.

 

Xilinx XC5VSX95T-2FF1136I (Date Code 1025) -39% Failure Rate - Program Error.

 

Kemet T495D107K010ATE080  (Date Code 230) - 100% Failure Rate 

high ESR.

 

 

Notes:

1. Statistics are calculated as a percentage of all lots dis-positioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart