Website Banner

Weeks 27-28

Report

 

Inspection Accept

32%

 

Electrical Testing Pass

74%

This Week in The Lab...
Weeks 27-28 Summary
Substandard Part Listing
week 27&28                          
                                   
White Horse Laboratories' Quality Report
Weeks 27-28, 2013

Weeks 27-28 Summary                                                                                                          

  

Electrical Testing yields continued to increase, despite a slight dip in Week 27. Yields have improved in 3 of the past four weeks, reaching 79% in Week 28 and 74% for the period, up 8 points over the previous period's 62%.

 

Nine different devices had a high failure rate in Electrical Testing, and two of those had a 100% failure rate.

 

Inspection results reached an all-time low in Week 27, plummeting to 21% before "recovering" to 42% in Week 28 and a 32% for the period, compared to 46% in the previous period.

Weeks 27-28 Quality Report

No capacitance
Samsung CL31B106KLHNNNE - Capacitance "Free" Capacitor

 

Substandard Part Listing

 

STMicroelectronics L200CH (Date Code not marked or labeled) - 6% Failure Rate - Random mix of High, Low, and No Output devices.

 

Infineon ADM6999X-A2-T-1-XP (Date Code not marked or labeled) - 27% Failure Rate - Shorted pins and bad protective diodes.

 

Altera EP2S180F1508I4 (Date Code 1005) - 6% Failure Rate - VCCIO shortted to GND.

 

Texas instruments TMS9995NL (Date Code not marked or labeled) -26% Failure Rate - Bad protective diodes.

 

Xilinx XC2V6000-4FF1152C (Date Codes 1023, 1031, 1026 and 1035) - 22% Failure Rate - Program error.

 

Altera EP2S90F1020I4N (Date Code 1219) - 100% Failure Rate - No output.

 

Samsung Electronics CL31B106KLHNNNE (Date Code not marked or labeled) - 100% Failure Rate - No capacitance.

   

Altera AT91SAM7S64C-AU (Date Code 1120) - 52% Failure Rate - Can not load the program with ID error.

 

International Rectifier PVT312LSTPBF (Date Code 1140) - 20% Failure rate - High leakage current.

Notes:

1. Statistics are calculated as a percentage of all lots dis-positioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart