Website Banner

Week 17-18 Report

 

Inspection Accept

61%

 

Electrical Testing Pass

71% 

This Week in The Lab...
Weeks 15-16 Summary
Substandard Part Listing
week 17 and 18                     
                                   
White Horse Laboratories' Quality Report
Weeks 17-18, 2013

Weeks 17-18 Summary                                                                                                          

  

Electrical Testing continued a three week climb after hitting a low of 42% in Week 15. Week 17 reached 64% and Week 18 climbed to 79%, reaching an average of 71% for the period. Let's hope this is a trend that continues.

 

With volumes increasing since March, the list and range of high failure rate devices reaching 12 different devices having a high failure rate.

 

Inspection started Week 17 on the same positive trend, improving to 72% before falling back down to 50% in Week 18, averaging just 61% for the period.

Weeks 17-18 Quality Report

blank check error
Blank check error- ST72T1412K2MCE

Substandard Part Listing

  

STMicroelectronics ST72T141K2MCE (Date Codes 0002 & 0003) - 100% Failure Rate - Blank check error (previously programmed).

 

Ali M6117D (Date Codes 0613 and 0607) - 7% Failure Rate - Open/short pins and bad protection diodes.

 

Atmel AT29C020-90PC (Date Codes 0429 and 0421) - 14% Failure Rate - Program & verify error.

 

Intersil X9455WV24IZ-2.7 (Date Codes 1017 and 1033) - 88% Failure Rate - wrong wiper value.

  

Yageo LG035M8200BPF-3525 (Date Code not marked or labeled) - 23% Failure Rate - Low Capacitance and high DF.

 

Intel HBLXT9785EHC.DO (Date Code 0820) - 70% Failure Rate - Open/Short pins and bad protection diodes.

 

On Semiconductor CMCPCI102BR (Date Code 0820) - 5% Failure Rate - Output channels not switching

 

Advanced Power Technology APT60N60BCSG (Date Code 1104) - 5% Failure Rate - Internal short circuit.

   

Texas instruments TMS9995NL (Date Code not marked or labeled) - 40% Failure Rate - Bad protection diodes.  

 

MicroSemi  APT8056BVR (Date Code 0603) - 46% Failure Rate - Low BVdss.

 

International Rectifier PVT312LSTPBF (Date Code 1140) - 23% failure rate - High on resistance.

 

Intersil X9250US24Z (Date Code not marked or labeled) - 46% Failure Rate - Wrong wiper values and resistance out-of-tolerance.

 

Infineon Technology  TCA965B (Date Code 0628) - 8% Failure Rate - High output A and wrong voltage detection.

 

Renesas UPD78F0058YGC-8BT-A (Date Code 0811) - 21% Failure Rate - Open/shorted pins and bad protective diodes.

  
Texas Instruments LM2825N-5.0/NOPB (Date Code 1028) - 9% Failure Rate - No output.
Notes:

1. Statistics are calculated as a percentage of all lots dis-positioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories