Website Banner

Week 45 Report

 

Inspection Accept

82.4%

 

Testing Pass

81.8%

week 45 chart                                  
White Horse Laboratories' Quality Report
Week 45, 2012

Weeks 45 Summary 

   

Some exciting news in Week 45 with both Inspection and Electrical Testing yields making sharp jumps with buyer acceptance following Inspection jumping to 82.4% in Week 45, up from 52.4% in Week 44.

 

Electrical Testing gained for the third straight week, up to 81.8% in Week 45, climbing from 73.1% in Week 44 and up over 20 points from Week 43's 60%.

Week 45 Quality Report, 2012

no MFG or part number marking for GW35HF60WD
No Traceable Markings on STGW35HF60WD Die

 

Substandard Part Listing 

 

Xilinx XC5VLX85T-1FFG1136I (Date Code 1143) - 37.92% failure - Program error with VCCIO,VCCINT short to GND.

 

STMicroelectronics   PSD854F2-90J(Date Code not marked or labeled) - 5% failure ID error.

 

Allegro Microsystems (Date Codes 1039, 1043, 0919, and 1037)- 6.55% failure - Uncharacteristic outputs.

 

STMicroelectronics STGW35HF60WD (Date Code not marked or labeled) - 50% failure - Short circuit.

Notes:

1. Statistics are calculated as a percentage of all lots dispositioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

 
We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories