Week 25 Report

 

Inspection:

52.6% Accept

 

Testing:

65.2% Pass

           
White Horse Laboratories' Quality Report
Week 25, 2012
 

Week 25 Summary 

 

We saw another setback in Week 25 on the back of some marginal improvements in Week 24. Lot acceptance from Electrical Testing dipped to 65% from Week 24's nearly 77% while lot acceptance from Physical Inspection sunk below 53% in Week 25 from 70.3% in Week 24. 

 

Results for the July poll are now showing 83% of respondents believe heightened buyer scrutiny is having a negatively impacting their sales.

 

Cast your vote, "Has the increase in buyer caution had a negative impact on sales and the market overall?".

 

 

Post your vote and view results on July's poll at http://conta.cc/MlepTE.

 

Week 25 Quality Report, 2012

 

Test values for BRY61 - Vds(on) should be less than 1.399V with measurements ranging from 13.49V to 14.62V
Substandard Part Listing

 

Texas Instruments   SN75436NE (Date Code 32) - 10% failure - low diode breakdown. 

 

Altera Corporation

EP2S90F1020I4N (Date Code 0807) - 11.8% failure - can not load program via JTAG and VCCIO shorted to GND.

 

NXP Semiconductor BRY61 (Date Code not marked or labeled) - 100% failure - all parts failed on Vak with readings between 13.49V to 14.62V.

  

MAXIM DS2433 (Date Code 1136) - 9.6% failure - program & verify error.

 

National Semiconductor TP3040V (Date Code 46) - 11.67% failure - 7 pieces failed wherein 2 pieces have no gain on PWR outputs and 5 pieces with no signal on all outputs.
Notes:

1. Statistics are calculated as a percentage of all lots dispositioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

 
We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories