Website Banner

Week 24 Report

 

Inspection:

70.3% Accept

 

Testing:

76.9% Pass

          
White Horse Laboratories' Quality Report
Week 24, 2012
 

Week 24 Summary 

 

We saw a mild recovery in Week 24's product quality from the dip in Week 23, which had followed from 4 weeks of steady, if not breathtaking, improvement. There was a marginal improvement in Physical Condition, with 70.3% of lots being in acceptable condition, and a more pronounced improvement in lots with relatively low failure rates, climbing to nearly 77% from about 60% in Week 23. 

 

July poll question, "Has the increase in buyer caution had a negative impact on sales and the market overall?".

 

So far the results are 75% of respondents believe the heightened scrutiny is having a direct impact on sales activity.

 

Post your vote on this July's poll at http://conta.cc/MlepTE.

 

Week 24 Quality Report, 2012

 

Blacktopped SUD50P04-08-GE3
Substandard Part Listing

 

Macronix International  AM29F040B-90PC (Date Code 0832) - 10% failure -digital ID error. 

 

Vishay SUD50P04-08-GE3(Date Code 1128) - 100% failure - High Rds(0n). See top-side photo.  

  
Altera Corporation  EP2S90F1020I4N (Date Code 0807) - 50% failure - Couldn't be programmed via JTAG and VCCIO shorted to GND.

 

 

  

 

 
Notes:

1. Statistics are calculated as a percentage of all lots dispositioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

 
We hope you find this report informative and usefull for your organization.

 

All the best,

Mark A. Rinehart
White Horse Laboratories