Website Banner

Week 28 Results

 

Inspection:

73% Accept

 

Testing:

81% Pass

Week 28 Quality Chart
White Horse Laboratories' Quality ReportWork Week 28, 2011

Week 28 Substandard Product Listing         

MAX472EPA Failure
MAX472EPA Low Output Voltage

 

Infineon BTS244Z-E3062A (Date Code 1023) - 11% failure - High Idss, low Vgs(th), and high Rds(on).

 

Axis ETRAX100LX (Date Code 0845) - 7% failure - bad protection diodes.

 

Intel N87V196KD (Date Code 0935) - 98% failure - blank-check error (previously programmed).

 

Maxim MAX472EPA (Date Code 0826) - 100% failure - low output voltage (disconnected diode in pin 3).

 

Notes:

1. Statistics are calculated as a percentage of all lots dispositioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

 
We hope you find this report informative and usefull for your organization.

 

All the best,

 


Mark A. Rinehart
White Horse Laboratories