Week 27 Results

 

Inspection:

65% Accept

 

Testing:

69% Pass

Week 27 Quality Chart
White Horse Laboratories' Quality ReportWork Week 27, 2011

Week 27 Substandard Product Listing

ISO1050DUBR Failure
ISO1050DUBR always high bus output

        
 

Texas Instruments ISO1050DUBR (Lot Code ZHD7) - 58% failure - non-switching bus and receiver outputs.

 

PMC Sierra/Agilent HDMP-1022 (Date Codes 0022, 0728, 0821, and 0822) - 27% failure - open pins and bad protection diodes.

 

PMC Sierra/Agilent HDMP-1024 (Date Codes 0016 & 0821) - 16% failure - open pins and bad protection diodes.

 

Infineon ITS716G (Date Code 1052) - 100% failure - high output voltage drop and devices remain active at Vbb < 4.5V even after coming from off-state.

 

Cypress CY7C269-50WMB (Date Code 0012) - 19% failure - blank-check error (previously programmed).

 

Lattice Semiconductor ISPLSI2064A80LTN100I (Date Code 0812) - 25% failure - blank-check error (previously programmed).

 

Epson S1D13700F01A100 (Date Code 0820) - 8% failure - open pins and bad protection diodes.

 

Texas Instruments BQ4017MC-70 (Date Code 1121) - 54% failure - program & verify error.

 

Infineon BTS721L1 (Date Code 1023) - 23% failure - one or all outputs having low state at Vbb=5V.

 

Toshiba 2SJ74-BL (Date Code 0912) - 100% failure - high Igss, low Idss, and high Vgs(off).

 

Infineon BTS716G (Date Codes 0934 & 0946) - 18% failure - uncharacteristic voltage drops and false output states.

 

Fujitsu 7MBR25NE-120 (Date Codes 0020 & 0603) - 100% failure - high Ices, high Imm, and high Vce(sat).

 

Cypress CY7C276 (Date Codes 0018 & 0025) - 36% failure - blank-check error (previously programmed).

 

Texas Instruments BQ4017MC-70 (Date Code 1121) - 84% failure - program and verify error.

 

Update from Week 26
  
In last week's report, Week 26, we listed a Microsemi device with date code 1052 that had a 95% failure rate for high forward voltage; however, the part number was inadvertantly left off of the listing. The part number is LSM150J3/TR.
  
We also listed an Infineon device with date code 1018 that had a 6% failure for high off-state drain current, Id(off). The part number listed was BSP14PL6906. The correct part number is BSP149L6906.
  
Our apologies for any inconvenience.
  
Notes:

1. Statistics are calculated as a percentage of all lots dispositioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

 
We hope you find this report informative and usefull for your organization.

 

All the best,

 


Mark A. Rinehart
White Horse Laboratories