Inspection:

69% Accept

 

Testing:

70% Pass

Week 26 Quality Chart
White Horse Laboratories' Quality ReportWork Week 26, 2011

Week 26 Substandard Product Listing

LT1785AIN8 Failure Unit
LT1785AIN8 Distorted Ouput Signal

        
 

Infineon BSP14PL6906 (Date Code 1018) - 6% failure - high off-state drain current, Id(off).

 

PMC Sierra/Agilent HDMP-1022G (Date Codes 0908, 0916, & 0938) - 6% failure - open and short pins, bad protection diodes.

 

PMC Sierra/Agilent HDMP-1024G (Date Code 0913) - 12% failure - open and short pins, bad protection diodes.

 

Infineon ITS716G (Date Code 1052) - 100% failure - high output voltage drop and devices remain active at Vbb < 4.5V even after coming from off-state.

 

Microsemi (Date Code 1052) - 95% failure - high forward voltage, Vf.

 

Xilinx XC95288-20HQ208I (Date Codes 0809 & 0835) - 27% failure - open pins and bad protection diodes.

 

Linear Technology LT1785AIN8 (Date Code 0918) - 100% failure - high input A and B current at +/- 60V common mode, clamping above 500mA.

 

Fairchild HGT1S7N60C3DS9A (Date Code 1017) - 46% failure - high collector-emitter saturation voltage, Vce(sat).

 

Epcos B82462-A4104-K (Date Code 0322) - 100% failure - high direct current resistance, DCR.

 

Toshiba TMP47P443VN (Date Code 0807) - 100% failure - blank-check error (previously programmed).

 

Semikron SKM200GAL125D (Date Code 0810) - 60% failure - high collector-emitter source current, Ices.

 

Xilinx XC17S30XLV08C (Date Code 0517) - 100% failure - blank-check error (previously programmed).

 

Lattice ISPLSI2064A80LTN100I (Date Code 0812) - 5% failure - blank-check error (previously programmed).

 

Agilent/PMC Sierra HDMP-1022 (Date Codes 0022, 0728, 0821 & 0822) - 27% failure - open, short pins and bad protection diodes.

 

Agilent/PMC Sierra HDMP-1024 (Date Codes 0016 & 0821) - 16% failure - open, short pins and bad protection diodes.

 

Ramtron FM24CL64-G (Date Code 1015) - 100% failure - program & verify error.

 

Notes:

1. Statistics are calculated as a percentage of all lots dispositioned within the given time period.

2. "Accept" is defined as customer acceptance of report device condition.

3. "Pass" is defined as meeting electrical parameters defined by the agreed upon test plan.

 