White Horse Labs

Week 40 Quality Report

Electrical Testing
- 55% Pass
Physical Inspection - 71% Accept
In Week 40, White Horse facilitated USD201,367.00 in successful transactions! 
 
Week 40 saw failures in a variety of device categories, rather than the predominantly discrete (passive and active) that we had been seeing in previous weeks.

Be on the lookout for the following high risk devices*:

 

  • Atmel AT45DB161D-TU, 27% failure - erase, program, and verify errors.
  • Atmel ATMEGA1281V-8MU, 36% failure - ID and blank check errors.
  • ON Semiconductor NTB60N06T4G, 100% failure - low power handling capability.
  • STMicroelectronics VNH3ASP30-E, 9% failure - wrong output state and high supply current at no load.
  • Maxim MAX6192AESA+, 40% failure - high and low output voltages (mixed bag).
  • Analog Devices AD1139J, 17% failure - static output voltage when writing any data.
  • Infineon BTS3142D, 6% failure - mixed parametric failures (mixed bag).

  • * Note: high risk is defined as devices with over a 5% failure rate in electrical testing.

    Quality drives a company's reputation, its bottom line and above all, its value.

    Analog Testing Stations
    Analog Testing Stations
     
    White Horse Laboratories
    Hong Kong and Shenzhen, China
    The Quality Control Company
     
    ISO 9001:2008 Certified
    ISO Certification
    ANSI/ESD S20.20-2007 Certified
    ESD Certification