White Horse Labs
Weeks 6-11 Quality Report
 
Electrical Testing
- 73.4% Pass
Physical Inspection - 82.8% Accept
In Weeks 6-11, White Horse facilitated USD795,670 in successful transactions! 
 
Passive and discrete component clones continue to flood the market. A combination of electrical test and physical inspection methods can identify these counterfeit components.
 
Be on the lookout for the following high risk devices: 
 
  • Dallas DS1386-32-120, 11% failure - failed program identification and verification
  • Texas Instruments TLC2272IPWR, 9.5% failure - no output signal and no gain
  • Toshiba 2SK1930, 100% failure - high gate threshold voltage
  • Burr Brown REF02BU, 14% failure - high and low output voltage
  • Micron MT47H64M16HR-3AT, 55% failure - open pins and bad protection diodes
  • AVX TPSB226K010R0500, 86% failure - high ESR
  • PMC Sierra/Agilent HDMP-1024G 32% - open pins and bad protection diodes
  • PMC Sierra/Agilent HDMP-1022G 5% - open pins and bad protection diodes
  • Vishay SI7884DP-T1-E3 100% - low breakdown voltage
  • Vishay P6KE68CA-E354, 41% failure - high breakdown voltage
  • Xilinx XC18V014PC201, 68% failure - failed program identification
  • Texas Instruments UC2844ADTRG4, 32.8% failure - high duty voltage
  • Infineon TLE4271-2G, 17.6% failure - unstable output voltage
  • ST Microelectronics STD30NF06T4, 51% failure - low gate threshold voltage
  • Texas Instruments SN65HVD235D, 100% failure - low bus differential and receiver output voltage
  • AVX TPME226M050R0075, 100% failure - high ESR
  • Panasonic EET-ED2G151CA, 5% failure - high ESR
  • Kemet T520D477M004ASE015, 100% failure - high ESR
  • ON Semi 1SMA5922BT3G, 100% failure - high leakage current
  • Linear Tech LT1013MH, 8% failure - output distortion
     
  • Quality drives a company's reputation, its bottom line and above all, its value.
     
    White Horse Agilent E4980A
    White Horse Laboratories
    Hong Kong and Shenzhen, China
    The Quality Control Company
     
     
    ISO Certification