Weeks 6-11 Quality Report
Electrical Testing - 73.4% Pass
Physical Inspection - 82.8% Accept |
|
In Weeks 6-11, White Horse facilitated USD795,670 in successful transactions!
Passive and discrete component clones continue to flood the market. A combination of electrical test and physical inspection methods can identify these counterfeit components.
Be on the lookout for the following high risk devices:
Dallas DS1386-32-120, 11% failure - failed program identification and verification
Texas Instruments TLC2272IPWR, 9.5% failure - no output signal and no gain
Toshiba 2SK1930, 100% failure - high gate threshold voltage
Burr Brown REF02BU, 14% failure - high and low output voltage
Micron MT47H64M16HR-3AT, 55% failure - open pins and bad protection diodes
AVX TPSB226K010R0500, 86% failure - high ESR
PMC Sierra/Agilent HDMP-1024G 32% - open pins and bad protection diodes
PMC Sierra/Agilent HDMP-1022G 5% - open pins and bad protection diodes
Vishay SI7884DP-T1-E3 100% - low breakdown voltage
Vishay P6KE68CA-E354, 41% failure - high breakdown voltage
Xilinx XC18V014PC201, 68% failure - failed program identification
Texas Instruments UC2844ADTRG4, 32.8% failure - high duty voltage
Infineon TLE4271-2G, 17.6% failure - unstable output voltage
ST Microelectronics STD30NF06T4, 51% failure - low gate threshold voltage
Texas Instruments SN65HVD235D, 100% failure - low bus differential and receiver output voltage
AVX TPME226M050R0075, 100% failure - high ESR
Panasonic EET-ED2G151CA, 5% failure - high ESR
Kemet T520D477M004ASE015, 100% failure - high ESR
ON Semi 1SMA5922BT3G, 100% failure - high leakage current
Linear Tech LT1013MH, 8% failure - output distortion
Quality drives a company's reputation, its bottom line and above all, its value.
|