The Gas Fireplace Industry faces a 
serious threat...

  • Can you afford a mechanical engineer to design a customized venting system for your showroom, plus the thousands of dollars required to remove and replace your existing showroom venting?
  • TSSA needs to hear your concerns as to how we can meet safety standards, but in a practical, cost effective manner that will not overstress your business in these difficult economic times.
  • Tens of thousands of dollars have already been spent by companies in fines plus showroom closures during peak business volumes.
Money Image

-------------------------------------------------------------------------

Safety Program FS-150-09
Date: ADVISORY July 2009
Subject: Gas Fireplace Showrooms
Sent to: Posted on TSSA Web-Site

The amended Section 4.1.3, for Ontario, of the CAN/CSA-B149.1-05 - "Natural Gas and Propane Installation Code" states: "An appliance, accessory, component, equipment or any other item shall be installed in accordance with the manufacturer's certified instructions and this Document".

The Technical Standards and Safety Authority (TSSA) recognizes the uniqueness of fireplace showrooms. Often there are 20 or more fireplaces in one showroom. The owner of building will not permit the tenant to cut 20 or more holes in the walls and ceiling to allow the venting of the fireplaces. The ability to operate a fireplace for demonstration purpose in a showroom is a critical selling function. Often the vents from one or more fireplaces are connected to a common header which does not comply with the certified instructions. In an effort to enforce the regulations, promote safety and recognizing the need for these showrooms to continue with their daily business, TSSA will consider variances which will allow the operation of these fireplaces for display purpose.

To apply for a variance, submit a completed variance application form along with the required deposit.

The application form shall reference Section 4.1.3 of the CAN/CSA-B149.1-05 Code. This form can be located at: http://www.tssa.org/regulated/fuels/fuelsForms.asp.

This variance covers only the venting of the fireplaces. All other aspects of the installation shall comply with the CAN/CSA-B149.1 installation code and the certified instructions. In submitting a variance the following information is required.

1. A design of your fireplace showroom. The design shall be submitted by professional Engineer knowledgeable in venting. The design shall deal with the installation of the fireplaces and shall include the following:
a. A list of fireplaces commonly vented. This shall include the manufacturer, model, input rate and type of fireplace (Direct Vent., Gravity Vent, Insert, Etc).
b. A drawing showing the venting arrangement. Included shall be dimensions, materials used, fabrication, termination, etc
c. Clearance to combustibles.
d. Combustion air source.

2. Design Considerations:
a. The venting system shall be capable of venting any one or all of the fireplaces connected to that header.
c. Demonstrate there is sufficient combustion air supply to handle all fuel burning appliances in operation at one time, including non fireplaces. Building exhaust fans need to be considered.
d. All fireplaces must be certified, no prototypes.

3. Other Requirements:
a. Fireplace showrooms shall be equipped with Carbon Monoxide Detectors which will alarm at 25 ppm. If there are living accommodations in a section of the building attached to the fireplace showroom, the Carbon Monoxide Detectors shall be interlocked to shut off the gas supply to the fireplaces in the event the C.O. level exceeds 10 ppm.
b. Fireplace showrooms shall be equipped with a fire suppression system (extinguisher or other)
c. All variances are subject to inspection and testing. 
---------------------------------------------------
The Ontario Chapter of HPBAC has organized meetings with TSSA in the following cities:
 
Ottawa
Wednesday, May 5, 2010
 
5:30pm
Enbridge Gas Distribution Inc.

400 Coventry Road, Ottawa ON

 
Toronto 
 Tuesday, May 11, 2010   
5:30pm
  Enbridge Gas Distribution Inc.
500 Consumers Road, Toronto ON
 
London
 
 Thurdsay, May 13, 2010  
5:30pm
Union Gas Ltd.
109 Commissioners Road, London ON
 
Join us at these important meetings and
let your voice be heard

----------------------------------------------------------------

 
Name:   _______________________________________________________________________
 
Number of Attendees:   __________ 
 
Company:  ____________________________________________________________________
 
Address:  _____________________________________________________________________
 
Telephone:  ____________________________    Fax:   _______________________________
 
Email Address:  ________________________________________________________________
 
Which Location will you be attending?  (please check one)     Ottawa _____    Toronto _____  London _____ 
 
HPBAC Member  _____    Non-member _____              (please check one)    
 
Admission:  Complimentary for current HPBAC members 
                      $20 per person for Non-members 
                 
Method of Payment:   VISA  ___ MC  ___ Cheque ___  (payable to HPBAC-Ontario Chapter)
 
Cardholder Name:___________________ Signature: ______________________________
 
Credit Card #: ______________________ exp date:  _____ 
 
Fax 
registration to: (800) 687-1383         or email to: hpbacontario@bellnet.ca
  
Don't miss your chance to be heard, register for the meeting now!!
HPBAC-Ontario Chapter
15 Silverwood Drive
Huntsville, Ontario P1H 1N1
(705)349-2220
Save
$20 
If you are not currently a member of HPBAC, your admission of $20.00 for attending one of the TSSA meetings will be discounted from your membership dues when you join in 2010.
Offer Expires: May 31, 2010