Modeling Hydronic Efficiency
By Peter Biondo
System efficiency in a hot water heating system or chilled water system is best carried out through the balanced distribution of energy. Water, in this case, is the carrier of energy. Therefore, to balance the energy within a building is to control the flow rate of water through the production side, starting at the power plant, and to manage the proportional flows through the distribution of sub mains, branches, and ultimately through the terminal units. The benefits of calibrating flow are comfortable and even temperatures throughout the building, plus energy efficiency at the production plant and throughout all parts of the system is maintained. Distributing energy within a hot or chilled water system is often referred to as "hydronic balancing."

Without hydronic balance, underflow or overflow within piping distribution can undermine the performance and efficiency of a system by up to 40%. Without balanced flow, temperatures are difficult to control. Boilers and chillers may short-cycle or run more often. As a result, some rooms may have considerable temperature swings, while other rooms farthest from the boiler or chiller may not get the energy required to meet thermostat demand. Balancing can correct the problem that some troubleshooters might regard as an issue of boiler sizing.

Uneven temperatures are compounded, especially during low load conditions in spring or fall when controls work to strike a balance between heating and cooling. Even the slightest swings of temperature can lower operating efficiencies significantly. If the average temperature in a building exceeds the nominal value by 2F, energy consumption is increased by 6 to10%. In cooling systems, temperatures that are 2F too low will result in an increase in energy consumption of about 15 %.

Hydronic balancing is an energy-saving feature carried out through the use of balancing valves. ASHRAE recommends placement of a balancing device at the following locations: pump discharge, chillers, cooling towers and boilers, risers and branch circuits, and the emitters or fan coils. Balanced distribution was once painstakingly engineered and constructed by tapering down pipe diameters and also through reverse return piping. The designer still has to work with correct pipe sizing, but with the use of balancing valves, presetting and measuring make it possible to insure energy balance throughout the entire system.

Balancing flow begins at the power plant. The boiler or chiller will not operate at its rated efficiency and output if the flow rate is not calibrated to design. Balancing at the boiler or chiller eliminates the problem of overflow, which can cause short cycling and loss of performance. Regulating flow is particularly important for multiple chillers or boilers controlled for staged operation. Balancing valves would correct the problem of one unit robbing flow from another during a combined operation. Without balancing valves on each unit, overflow through one appliance may cause underflow through another. While overflow causes short cycling and lowers the unit's rated efficiency, it also has a tendency to reduce the expected service life of the equipment. Underflow, on the other hand, can damage a boiler or chiller. A boiler's heat exchanger may crack due to temperature stress. Underflow for a chiller increases the chances of tubes freezing and causing damage to the unit. Balancing at the power plant eliminates flow issues and insures delivery of the rated output into the water from each unit.

From the pump discharge, getting the right balance and flow to all the branches of piping and into each terminal unit is a matter of pushing the flow out to the farthest reaches of the building with balancing devices. The process of hydronic balancing is conducted in an organized procedure done by an experienced commissioning agent. Whether automatic valves, handwheel calibrated balancing valves, or circuit setters are installed, the agent's responsibility is to insure that the hydronic system is operating at design specifications. Understanding how a system is brought into balance is best explained through the work of a commissioning agent.

Pushing the flow out to the farthest branches and terminal units is a matter of creating resistance in the sub mains, branches, and terminals that are closest to the boiler or chiller. The balancing valve, by means of a handwheel-turned dropped stem or an automatic venturi, adjusts the resistance to flow and enables the commissioner to have a reference place to measure the flow rate. The commissioning agent begins with the balancing valves at the power plant and then works with the balancing valves at the sub mains, starting from the closest valve from the pump and ending at the farthest valve. This process is carried out for balancing valves on the risers, the branches and finally at the terminal units (such as fan coils). The commissioner always begins at the closest balancing valve to the pump discharge and works his way out to the farthest balancing valve for each group and sub group.

Calibrated balancing valves (CBVs) have many practical features that are serviceable to the commissioning agent and the service technician. CBVs give the commissioning agent the ability to preset the valve for the desired flow rate, and then to adjust and measure at the CBV the precise flow rate within 3% measuring accuracy. The multi-turn handle allows for a wide range of flow adjustment. CBVs are designed to have low pressure drops across the valve (1psi or 2.3 ft of head minimum drop for test and balance) and offer high Cv values. This affords lower energy consumption at the pump over automatic balancing valves. A service feature unique to CBVs is the built-in memory position at the top calibrated setting, and the valve can be used as a positive shut-off valve. Also, adapters can be put in place of the measuring ports for draining and filling. These features allow for the CBVs to be utilized for servicing the hydronic system. With the memory stop in place, opening back the valve handwheel to memory resets the balancing valve as the commissioning agent left it. Handwheels can also be locked.

Balancing valves are particularly important at fan coils. Energy output at the fan coil is dependant on flow, water temperature, and air velocity. All three must be in balance for the coil to operate at its rated output. This is particularly important in a variable flow system, when a two-way proportional control valve is installed at a fan coil. The relationship between the control signal and the resulting thermal power from the coil, referred to as the circuit characteristic, determines the controllability of the system. In variable flow systems, differential pressure across the control valve must not vary too much in order to prevent the circuit characteristic from distorting. Without pressure stabilization valves, small changes in the control signal, even tiny alterations, may cause large swings in thermal output. On the other hand, any actions from the control signal could result in marginal changes of thermal output. Balancing valves stabilize differential pressures at the control valve and improve the circuit characteristic. The result is a better control relationship from changes in the proportional control valve to the thermal output at the coil. No matter how advanced the controls, an effective measure to improve the circuit characteristic across a fan coil includes a means to set the design flow rate for the fan coil, at the control valve fully open so the thermal output will respond more linearly to proportional flow.

Balancing valves for fan-coil units and surface heating systems are also manufactured in valve combinations with controls. These valves offer the benefit of a control valve with a linear flow characteristic, which is advantageous when using proportional actuators that have linear stroke behavior. These combination valves are space savers in air handler units and require less labor cost to install than building individual components together. The flow range is easily viewed and can be set with the help of a lockable handwheel. These valves can include test points for measuring the regulated flow.
 
Heating and air conditioning technology has come a long way. Energy efficient boilers and chillers, intelligent controllers and building management systems have replaced yesterday's crude and often oversized systems. But one problem remains - complaints about comfort persist, while at the same time HVAC systems are using 40% more energy than intended. Even when the most recent technology has been implemented, property managers can't determine why a building cannot achieve temperature balance. Hydronic balancing isn't just a good idea, it is good practice. Balancing valves are an important component throughout the hydronic system to evenly distribute the energy for heating or cooling a building. Quite frequently, insufficient attention is paid to balancing a hydronic system-inexpensive valves are chosen, poor choices are made, and efficiencies that could be gained are lost. You wouldn't drive circles around the block to get where you want to go-you want to find the most efficient route to get to where you want to be. Hydronic balancing delivers the energy throughout the piping network or roadways where it needs to go efficiently and right on time.
 
Please contact The CalHot Team to make sure that you have all the correct options  for your Hydronic application.
 
Featured for the Month:
 
                                             
            
                                    Check out the new mini Hi-Delta!
 
Key Features:
19 models from 100,000 to 2,340,000 BTUH
  • All models indoor/outdoor certified
  • Efficiency: 84% Boilers- standard
  • 85% AFUE HD101-HD301
  • 87% Available on Models 302BE-2342BE
  • 85% Water Heaters- standard
  • 98% Condensing system available
    (see Specialty Models)
  • Patented burner "security blanket" enhances staged
    combustion, minimizes installation and start-up issues,
    and protects burners from metal fatigue
  • 105F minimum inlet water capability on standard models;
    120F on 87% boilers
  • Copper finned tube heat exchanger; Cupro-nickel available
  • AB 1953 low lead compliant
  • Bronze headers standard on water heaters, optional
    on boilers
  • Sidewall venting ready; No extractor needed for
    most applications
  • Ducted combustion air ready; TruSealTM CSA-certified
    direct-vent available
  • Status display and on-baord diagnostic center, real english, no
    codes.
  • Meets all NOx regulations
    Options
  • G-20 - Low Gas Pressure (Models 302B-2342B) 
  • CSA-certified for 4" WC supply pressure, natural gas only.
  • D-14 - Rear vent option available at time of order
  • D-21- TrueSeal direct vent air intake system
  • A-6 - Right hand water connection
  •  
    The CalHot Team wants to make sure that everyone knws about the NEW space saver Baby Hi- Deltas are available so please call us to order it TODAY!
     
                           

     Tax Credits:

                                                 
    Update  2010:
     
    Form 5695, Residential Energy Credits, available on-line.
    IR-2009-98,
     
     
    People can now weatherize their homes and be rewarded for their efforts. According to the Internal Revenue Service, homeowners making energy-saving improvements this fall can cut their winter heating bills and lower their 2009 tax bill as well.
    The American Recovery and Reinvestment Act (Recovery Act), enacted earlier this year, expanded two home energy tax credits: the nonbusiness energy property credit and the residential energy efficient property credit.
     
    Nonbusiness Energy Property Credit
    This credit equals 30 percent of what a homeowner spends on eligible energy-saving improvements, up to a maximum tax credit of $1,500 for the combined 2009 and 2010 tax years. The cost of certain high-efficiency heating and air conditioning systems, water heaters and stoves that burn biomass all qualify, along with labor costs for installing these items. In addition, the cost of energy-efficient windows and skylights, energy-efficient doors, qualifying insulation and certain roofs also qualify for the credit, though the cost of installing these items does not count.
    By spending as little as $5,000 before the end of the year on eligible energy-saving improvements, a homeowner can save as much as $1,500 on his or her federal income tax return. Due to limits based on tax liability, other credits claimed by a particular taxpayer and other factors, actual tax savings will vary. These tax savings are on top of any energy savings that may result.
    Residential Energy Efficient Property Credit
    Homeowners going green should also check out a second tax credit designed to spur investment in alternative energy equipment. The residential energy efficient property credit, equals 30 percent of what a homeowner spends on qualifying property such as solar electric systems, solar hot water heaters, geothermal heat pumps, wind turbines, and fuel cell property. Generally, labor costs are included when calculating this credit.  Also, no cap exists on the amount of credit available except in the case of fuel cell property.
    Not all energy-efficient improvements qualify for these tax credits. For that reason, homeowners should check the manufacturer's tax credit certification statement before purchasing or installing any of these improvements. The certification statement can usually be found on the manufacturer's website or with the product packaging. Normally, a homeowner can rely on this certification.  The IRS cautions that the manufacturer's certification is different from the Department of Energy's Energy Star label, and not all Energy Star labeled products qualify for the tax credits.
    Eligible homeowners can claim both of these credits when they file their  federal income tax return. Because these are credits, not deductions, they increase a taxpayer's refund or reduce the tax he or she owes. An eligible taxpayer can claim these credits, regardless of whether he or she itemizes deductions on Schedule A. Use Form 5695, Residential Energy Credits, to figure and claim these credits
     
     
    The CalHot Team can help you with all your solar needs to make it easier. Please call us to order your solar needs TODAY!

    Our Manufacturers:

     
      
      
     
     
     

    Golf Tournament:

     Last Reminder!
                                                       
    Plumbing*Heating*Cooling
    Contractors Association of
    Orange, Riverside &
    San Bernardino Counties
    Annual Golf Classic
    Thursday, May 27th, 2010
     
     Presents:
     
    Annual Golf Classic
    Come follow the Course of Nature at the beautiful
    Hidden Valley Golf Course in Norco, it's a par 72
    Championship Golf Course
    Soft Spike Shoes, please!
    Proper golf attire required
    If you are unable to play but
    would like to contribute, sponsorships are available
    and raffle gifts are greatly appreciated.
     
     
     
     
    Our Location: 
     
    From 405 Freeway North or South

    Exit on Inglewood Ave.
     
    Go South on Inglewood Ave. toward Manhattan Beach Blvd.
      
    Turn left on Manhattan Beach Blvd.
     
    Turn  left on Condon Ave. (
    right after you cross the railroad tracks)
     
    Turn left at the 3rd driveway into the brown business complex.
     
    Go straight until you see our Will Call building on the right.
     
    Then walk to the Will Call counter
    .
     

     

     

    Open 24/7: 
     
    For your emergency product needs, The CalHot Team is available after
    hours, weekends and on holidays. 

    Please contact us for any questions or comments. 
     
    The CalHot Team
    w.310.725.5144
    f. 310.643.8499
    calhotteam@calhot.com